(FC) is initial footcandles at center of
beam.Beam length (L) and beam width (W)
are to where the candlepower is reduced to
50% of the center beam candlepower.
CBCP is center beam candlepower. (C) is
distance to the center of the beam.
Lamp data shown is typical, and is based on
bare lamp photometrics. Contact lamp man-
ufacturers for availability and performance.
Accent Lighting Performance Data
DFC L W
DC FC L W
DC FC L W
Lamps
Beam Spread
CBCP
Rated
(To 50% CBCP) Life (Hrs.)
0° Aiming Angle 30° Aiming Angle 30° Aiming Angle
PAR20 Halogen Line Voltage Lamps
PAR16 Halogen Line Voltage Lamps
6 83 0.8 0.8
8 47 1.1 1.1
10 30 1.4 1.4
12 21 1.7 1.7
5 2.9 78 0.9 0.8
7 4.0 40 1.3 1.1
9 5.2 24 1.7 1.5
11 6.4 16 2.1 1.8
2 3.5 94 1.1 0.6
3 5.2 42 1.7 0.8
4 6.9 23 2.3 1.1
5 8.7 15 2.8 1.4
3000 2500
35W PAR20
NSP 8˚
3 100 1,6 1.6
5 36 2.7 2.7
7 18 3.8 3.8
9 11 4.8 4.8
3 1.7 65 2.2 1.9
5 2.9 23 3.7 3.1
7 4.0 12 5.1 4.3
9 5.2 76.6 5.6
1 1.7 113 2.7 1.1
2 3.5 28 5.5 2.1
3 5.2 13 9.2 3.2
4 6.9 7 10.9 4.3
900 2500
35W PAR20
NFL 30˚
6 89 1.6 1.6
8 50 2.1 2.1
10 32 2.6 2.6
12 22 3.2 3.2
5 2.9 83 1.8 1.5
7 4.0 42 2.5 2.1
9 5.2 26 3.2 2.7
11 6.4 17 3.9 3.3
2 3.5 100 2.2 1.1
3 5.2 44 3.3 1.6
4 6.9 25 4.4 2.1
5 8.7 16 5.6 2.6
3200 2000
50W PAR20
SP 15˚
4 116 1.9 1.9
6 51 2.9 2.9
8 29 3.8 3.8
10 19 4.8 4.8
3 1.7 134 2.0 1.7
5 2.9 48 3.3 2.8
7 4.0 25 4.6 3.9
9 5.2 15 5.9 5.0
1 1.7 231 2.3 1.0
2 3.5 58 4.6 1.9
3 5.2 26 7.0 2.9
4 6.9 14 9.3 3.8
1850 2000
50W PAR20
NFL 27˚
6 167 0.8 0.8
8 94 1.1 1.1
10 60 1.4 1.4
12 42 1.7 1.7
5 2.9 156 0.9 0.8
7 4.0 80 1.3 1.1
9 5.2 48 1.7 1.5
11 6.4 32 2.1 1.8
2 3.5 188 1.1 0.6
3 5.2 83 1.7 0.8
4 6.9 47 2.3 1.1
5 8.7 30 2.8 1.4
6000 2000
50W PAR20
NSP 8˚
3 67 2.2 2.2
5 24 3.6 3.6
7 12 5.1 5.1
9 7 6.6 6.6
3 1.7 43 3.0 2.5
5 2.9 16 5.1 4.2
7 4.0 8 7.1 5.9
9 5.2 5 9.1 7.6
1 1.7 75 4.8 1.5
2 3.5 19 9.7 2.9
3 5.2 8 14.5 4.4
4 6.9 5 19.3 5.8
600 2500
35W PAR20
WFL 40˚
6 139 1.0 1.0
8 78 1.4 1.4
10 50 1.7 1.7
12 35 2.1 2.1
5 2.9 130 1.2 1.0
7 4.0 66 1.6 1.4
9 5.2 40 2.1 1.8
11 6.4 27 2.6 2.2
2 3.5 156 1.4 0.7
3 5.2 69 2.1 1.0
4 6.9 39 2.9 1.4
5 8.7 25 3.6 1.7
5000 2000
60W PAR16
NSP 10˚
3 144 1.6 1.6
5 52 2.7 2.7
7 27 3.8 3.8
9 16 4.8 4.8
3 1.7 94 2.2 1.9
5 2.9 34 3.7 3.1
7 4.0 17 5.1 4.3
9 5.2 10 6.6 5.6
1 1.7 163 2.7 1.1
2 3.5 41 5.5 2.1
3 5.2 18 8.2 3.2
4 6.9 10 10.9 4.3
1300 2000
60W PAR16
NFL 30˚
7 153 1.2 1.2
10 75 1.7 1.7
13 44 2.3 2.3
16 29 2.6 2.6
6 3.5 135 1.4 1.2
9 5.2 60 2.1 1.8
12 6.9 34 2.8 2.4
15 8.7 22 3.5 3.0
2 3.5 234 1.4 0.7
3 5.2 104 2.1 1.0
4 6.9 59 2.9 1.4
5 8.7 38 3.6 1.7
7500 2000
75W PAR16
NSP 10˚
4 119 2.1 2.1
6 53 3.2 3.2
8 30 4.3 4.3
10 19 5.4 5.4
3 1.7 137 2.2 1.9
5 2.9 49 3.7 3.1
7 4.0 25 5.1 4.3
9 5.2 15 6.6 5.6
1 1.7 238 2.7 1.1
2 3.5 59 5.5 2.1
3 5.2 26 8.2 3.2
4 6.9 15 10.9 4.3
1900 2000
75W PAR16
NFL 30˚
Calculite
®
Evolution Incandescent Adjustable Accent C4P20A
Page 2 of 2 4 1/2” Aperture PAR20 / PAR16 Reflector Trim
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.