Lighting Systems Baselyte-BSL21
Page 2 of 7 1 Light T8 Indirect
Lightolier a Genlyte Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.1
Job Information Type:
Performance
Candlepower Curve Candlepower Summary Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW = suspended standard white
Dust CoverEnd Set
BSLJS = suspended joiner
BSLDCS = 4’ suspended dust cover
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
12’
Module
Joiner End Set Mount
Power
Mount*
4’ run 1 1 1 1
8’ run 1 1 1 1
12’ run
1 1 1 1
16’ run
2 1 1 2 1
20’ run 1 1 1 1 2 1
24’ run 2 1 1 2 1
28’ run 2 1 2 1 3 1
32’ run 1 2 2 1 3 1
Report No: 2101588
Lamps: F32T8
Lumens per Lamp: 2950
Efficiency: 89.6%
Up: 100.0% Down: 0.0%
Zonal Lumen Summary
ZONE LUMENS %BARE LAMP %LUMINAIRE
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@






















CANDLEPOWER SUMMARY
ZONE CANDLEPOWER
DEG. 0 22.5 45 67.5 90
180 639 639 639 639 639
175 636 637 640 641 641
165 613 619 632 641 645
155 571 584 614 639 649
145 507 533 588 633 650
135 427 471 555 622 647
125 331 402 520 605 636
115 225 333 480 560 592
105 114 266 374 388 419
95 25 83 121 102 122
90 1 1 8 1 9
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
5 0 0 0 0 0
0 0 0 0 0 0
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 85 85 85 73 73 73 49 49 49
1 74 71 68 63 60 58 43 41 40
2 64 59 55 55 51 47 37 35 33
3 56 50 46 48 43 39 33 30 27
4 49 43 38 42 37 33 29 26 23
5 44 37 32 37 32 28 26 22 20
6 39 32 27 33 28 24 23 19 17
7 35 28 24 30 24 21 20 17 14
8 31 25 20 27 21 18 18 15 12
9 28 22 18 24 19 16 17 13 11
10 26 20 16 22 17 14 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
2645
2645
0 0
100.0
100.0
0
89.7
89.7
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0 85 85 85 73 73 73 49 49 49
1 74 71 68 63 60 58 43 41 40
2 64 59 55 55 51 47 37 35 33
3 56 50 46 48 43 39 33 30 27
4 49 43 38 42 37 33 29 26 23
5 44 37 32 37 32 28 26 22 20
6 39 32 27 33 28 24 23 19 17
7 35 28 24 30 24 21 20 17 14
8 31 25 20 27 21 18 18 15 12
9 28 22 18 24 19 16 17 13 11
10 26 20 16 22 17 14 15 12 10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP %LUMINAIRE
0-90
90-180
0-180
2645
2645
0 0
100.0
100.0
0
89.7
89.7
Note: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.